TOC analizator Formacs HT with Primacs MCS add-on

High Temperature Total Organic Carbon Analyzer The FormacsHT Total Organic Carbon high temperature catalytic combustion system features a versatile modular design and excellent performance for the analysis of Total Carbon (TC), Total Inorganic Carbo

TOC analizator Formacs HT with Primacs MCS add-on
TOC analizator Formacs HT with Primacs MCS add-on
TOC analizator Formacs HT with Primacs MCS add-on

Contacts and Location

Description

High Temperature Total Organic Carbon Analyzer The FormacsHT Total Organic Carbon high temperature catalytic combustion system features a versatile modular design and excellent performance for the analysis of Total Carbon (TC), Total Inorganic Carbo

Specification

General Characteristics

  • Analytes: Total Carbon (TC), Total Inorganic Carbon (TIC), Total Organic Carbon (TOC), Non Purgable Organic Carbon (NPOC), Purgable Organic Carbon (POC), Dissolved Organic Carbon (DOC)
  • Method: High temperature catalytic combustion with Infra Red Detection (NDIR)
  • Samples: Drinking-, ground-, waste-, sea-, cooling-, surface-, pharmaceutical waters, industrial production etc.
  • Sample introduction: By automated septumless rotary injection port with integrated wash position for sample line and injection needle
  • Compliancy: EPA 415.1., Standard methods 5310B, DIN 38409 H3, ASTM D-5173, USP <643>, ISO 8245, EN 1484, USEPA 9060, etc.

Operational and Performance Characteristics

  • Measuring range: Up to 25,000 mg/l C
  • Detection limit: 0.05 mg/l C (lower detection limits can be achieved but depend on laboratory conditions)
  • Reproducibility: Ranges < 5 ppm within 2% f.s. - Ranges > 5 ppm within 1.5 % f.s. (full scale)
  • Analysis time: Approx. 3 minutes for TC or TIC
  • Injection volume: 10-250 μl
  • Particle sizes: Maximum 450 μm (800 μm optional)
  • Furnace temperature: Up to 950°C
  • Alarms: Carrier-gas flow, furnace temperature, Peltier cooler temperature
  • Software and data processing: Area calculation. Multi-point linear regression, automatic exclusion of results, recalculation, statistics, table editing, automatic start-up and shutdown, 21 CFR Part 11 compliant

Physical Characteristics

  • Gas: CO2 - free synthetic or zero grade air at 200 ml/min 150 kPa
  • Power requirements: 100 – 120 V, 220 – 240 V, 60/50 Hz
  • Power consumption: Max 600 VA

Features

  • Stand-alone TOC operation or with auto-sampler
  • Homogenization by automated stirring (rod or magnetic)
  • Robust rotary septumless injection ports
  • Integrated Peltier cooler for optimum moisture removal
  • Large variety of vial sizes including septum-closed vials
  • Allows a true system blank analysis
  • Method according to EPA 415.1, Standard Methods 5310B, DIN 38409 H3, ASTM D-5173, USP <643>, EU 2.2.44, ISO 8245, EN 1484, USEPA 9060A

PrimacsMCS Features

  • Automatic balance interfacing
  • Sample weights up to 3 grams
  • Range of 1 mg to 40 mg absolute carbon
  • Unique vertical sample introduction system
  • Reusable quartz sample crucibles
  • Economical concept
  • Requires minimal bench space
  • Integrated TC and TIC reactors
  • No sample pretreatment required
  • Method according ISO 10649, ISO 13137, EN 13639 , EPA 415.1, ASTM D-2579 US, EPA 9060A

Services

analyze TOC in:

  • Drinking water
  • Waste water
  • Surface water
  • Sea water
  • High saline waters
  • Process control
  • Pharmaceutical industry
  • Soil extracts
  • Others