Share this
Map

Reaction monitoring Raman Analyzer

In conjunction with a high-performance CCD detector and Kaiser's proprietary HoloPlex™ grating technology, the RAMANRXN1™ spectrometer is capable of providing fast, simultaneous, full spectral collection of Raman data at high spectral resolution. Th

Reaction monitoring Raman Analyzer

Contacts and Location

Description

In conjunction with a high-performance CCD detector and Kaiser's proprietary HoloPlex™ grating technology, the RAMANRXN1™ spectrometer is capable of providing fast, simultaneous, full spectral collection of Raman data at high spectral resolution. The RAMANRXN SYSTEMS™ suite of analyzers is ideal for analyzing, monitoring and controlling chemical processes. Raman spectroscopy provides the chemical specificity of a mid-IR analyzer with the ease of sampling of a near-IR analyzer.

Specification

Standard configuration:

• Measurement: Raman • Laser Wavelength: 532nm, 785nm • Spectral Coverage: 100-4375cm-1 (532nm) 100-3425cm-1 (785nm) • Probe head: MR-Probe-785 • Impressions Optics: IO018S-NIR • Enclosure Type: Painted Steel, Aluminum and Plastic • Dimensions: 23″ x 17,63″ x 8″ (width x lenght x height) (58 x 45 x 20cm) • Weight: 61 lbs. (28kg)

System requirements:

• Temperature: 20°C (Min) / 25°C (Max) • Relative Humidity: 20 to 80%, non-condensing • Input Voltage: 110-240 VAC, 50-60Hz Standard • Max Power: <200 Watts Max (startup) <135 Watts Typical • Warm up time: 20min • User interface: Approved PC Operating Windows 7, 32Bit Professional

Services

Applications:

• Crystallization studies • Hydrogenations • Catalysis investigations • Polymorphic form ID • Emulsion polymerizations

System benefits:

• Specifity to Mid-IR, but with the Ease of Sampling of Near-IR • No sample preparation required • Accurate transfer of calibration models from Lab-to-Pilot-to-Plant Systems • Visualize chemical trends

Sampling Technology:

• Fiber-optic probehead for in situ, real time analysis • Optimized for low-wavenumber performance • Alloy C276 immersion optics: temperature up to 450°C, pressures to 3000 PSI • Non-contact optics for focusing beam trough site windows

RAMANRXN1™ system are the preferred analytical tool for in situ crystalline, polymorph, and aqueous-based reaction analysis and monitoring.

Funding Source

Other -
Back to all

Manufacturer

Kaiser Optical Systems

Model

Raman RXN1TM Analyzer

Access Level

Restricted

Contract price
Enquire
or

Permanent Link

Similar equipment
0 items in cart
Total: 0
You have no items in a cart
Go to checkout
Go Enquire