System consists of temperature and heat flux sensors, wireless data logger and data-processing software for in-situ measurements of U-value (thermal transmittance) for building structures
Specification
Temperature sensors: -75°C to +250°C. Heat flow plates: dimensions 25x25 cm. Soil heat flux sensors: sensor type: thermopile with film heater, sensitivity (nominal): 50 μV W-1 m-2, temperature range: -30°C to +70°C, accuracy: ±3% of reading. Data logging running on battery – up to 10 days.
Services
In-situ measurements of U-value (thermal transmittance) for a building structures under real operating conditions during heating season (at least 15°C temperature difference is needed)
Funding Source
EU Structual Funds (ERAF, ESF) | - |
---|
Manufacturer
Ambinstra Ltd.