Atomic absorption spectrometer PerkinElmer

The AAnalyst™ 600 is equipped with a unique solid-state detector for unmatched analytical performance over the entire AA wavelength range. High performance, single-path optics provide AAnalyst 600 spectrometers with maximum light throughput and an ex

Atomic absorption spectrometer PerkinElmer

Contacts and Location

Description

The AAnalyst™ 600 is equipped with a unique solid-state detector for unmatched analytical performance over the entire AA wavelength range. High performance, single-path optics provide AAnalyst 600 spectrometers with maximum light throughput and an exceptional signal-to-noise ratio for superior detection limits and precision. The spectrometer and furnace are controlled using WinLab 32 software, which has been designed for unmatched ease-of-use and simplified operation with single keyboard control. An easily accessible eight-lamp holder includes built-in lamp power supplies for both hollow cathode and electrodeless discharge lamps. Automatic lamp selection and alignment further improve operating convenience and productivity. The state-of-the-art detector and high performance optical system are combined with a Transversely Heated Graphite Atomizer (THGA) furnace assembly, longitudinal Zeeman-effect background correction, enhanced STPF technology, and True Temperature Control (TTC) to provide unmatched graphite furnace AA performance.

Specification

  • Single-beam optical system
  • Wavelength range: 190-900 nm
  • Diffraction grating: 1800 lines/mm blazed at 236 nm and 597 nm
  • Grating area: 64 x 72 mm
  • Reciprocal linear dispersion: 1.6 nm/mm (nominal)
  • Focal length: 267 mm
  • Wide-range segmented solid-state detector, including a built-in low-noise CMOS charge amplifier array.
  • Automatic 8-lamp holder with built-in power supplies for hollow cathode and electrodeless discharge Lamp Selection lamps
  • Computer-controlled lamp selection and alignment via WinLab32™ software. Operating parameters are automatically set when using PerkinElmer® Lumina™ hollow cathode lamps.
  • Certification: ISO 9001; The WinLab32 software provides required control parameters for GLP and instrument performance verification.
  • Safety: EN 61010-1, EN 61010-2-061, CSA C22.2 No. 1010.1, CSA C22.2 No. 1010.2.061.
  • EMC Standards EN 61326, EN 55011, EN 61000-3-2, EN 61000-3-3

Services

9 Service (that can be provided with this item) Microelemental analysis of water, soil, sediment, biological materials, food products, agricultural products, etc.