Spectrofluorometer FluoroMax-3, Jobin Yvon

FluoroMax®-3 is self-contained, fully automated spectrofluorometer system. Data output is viewed on a PC, while printouts may be obtained via an optional plotter or printer. All FluoroMax®-3 functions is under the control of DataMax spectroscopy soft

Spectrofluorometer FluoroMax-3, Jobin Yvon

Contacts and Location

Contact 1 Māra Grūbe
Enquire about this equipment
Organisational Unit Institute of Microbiology and Biotechnology
    University of Latvia
Building Rīga, Jelgavas 1
Room 529

Description

FluoroMax®-3 is self-contained, fully automated spectrofluorometer system. Data output is viewed on a PC, while printouts may be obtained via an optional plotter or printer. All FluoroMax®-3 functions is under the control of DataMax spectroscopy software. The main parts of the Fluoro- Max®-3 spectrofluorometer system are: • State-of-the-art optical components • A personal computer • DataMax for Windows™, the driving software.

Specification

Excitation Source: 150-W xenon, continuous output, ozone-free lamp Optics: All-reflective, for focusing at all wavelengths and precise imaging for microsamples. Dispersion: 4.25 nm mm–1 Spectrometer: Single-grating excitation and emission spectrometer (standard). Spectrometer are f/3.5 Czerny-Turner design with classicallyruled gratings and all-reflective optics, using 1200-grooves/mm gratings: Resolution: 0.3 nm Maximum scan speed: 200 nm s–1 Accuracy: ±0.5 nm Step Size: 0.0625–100 nm Range: 0–950 nm (physical) Gratings: Excitation 330-nm blaze (220–600 nm optical range) Emission 500-nm blaze (290–850 nm optical range) Sample Module: The sample module also has a removable gap-bed assembly for sampling accessory replacement. Detectors: • Calibrated photodiode for excitation reference correction from 200–980 nm. • Emission detector is an R928P for high sensitivity in photoncounting mode (180–850 nm). High voltage = 950 V, linearity to 2 × 106 counts s–1, < 1000 dark counts s–1. Sensitivity: Double-distilled, de-ionized, ICP-grade water-Raman scan 2500:1 S/N at 397 nm, 5-nm bandpass, 1-s integration time, background noise first standard deviation at 450 nm. 300 000 counts s–1 using these conditions. Excitation shutter: Computer-controlled Integration time: 0.001–160 s Slit width: 0–30 nm bandpass, continuously adjustable via host computer

Services

A spectrofluorometer is an analytical instrument used to measure and record the fluorescence of a sample. While recording the fluorescence, the excitation, emission, or both wavelengths may be scanned. With additional accessories, variation of signal with time, temperature, concentration, polarization, or other variables may be monitored.

Funding Source

EU Structual Funds (ERAF, ESF) -
Back to all