High Temperature Total Organic Carbon Analyzer The FormacsHT Total Organic Carbon high temperature catalytic combustion system features a versatile modular design and excellent performance for the analysis of Total Carbon (TC), Total Inorganic Carbo
General Characteristics
- Analytes: Total Carbon (TC), Total Inorganic Carbon (TIC), Total Organic Carbon (TOC), Non Purgable Organic Carbon (NPOC), Purgable Organic Carbon (POC), Dissolved Organic Carbon (DOC)
- Method: High temperature catalytic combustion with Infra Red Detection (NDIR)
- Samples: Drinking-, ground-, waste-, sea-, cooling-, surface-, pharmaceutical waters, industrial production etc.
- Sample introduction: By automated septumless rotary injection port with integrated wash position for sample line and injection needle
- Compliancy: EPA 415.1., Standard methods 5310B, DIN 38409 H3, ASTM D-5173, USP <643>, ISO 8245, EN 1484, USEPA 9060, etc.
Operational and Performance Characteristics
- Measuring range: Up to 25,000 mg/l C
- Detection limit: 0.05 mg/l C (lower detection limits can be achieved but depend on laboratory conditions)
- Reproducibility: Ranges < 5 ppm within 2% f.s. - Ranges > 5 ppm within 1.5 % f.s. (full scale)
- Analysis time: Approx. 3 minutes for TC or TIC
- Injection volume: 10-250 μl
- Particle sizes: Maximum 450 μm (800 μm optional)
- Furnace temperature: Up to 950°C
- Alarms: Carrier-gas flow, furnace temperature, Peltier cooler temperature
- Software and data processing: Area calculation. Multi-point linear regression, automatic exclusion of results, recalculation, statistics, table editing, automatic start-up and shutdown, 21 CFR Part 11 compliant
Physical Characteristics
- Gas: CO2 - free synthetic or zero grade air at 200 ml/min 150 kPa
- Power requirements: 100 – 120 V, 220 – 240 V, 60/50 Hz
- Power consumption: Max 600 VA
Features
- Stand-alone TOC operation or with auto-sampler
- Homogenization by automated stirring (rod or magnetic)
- Robust rotary septumless injection ports
- Integrated Peltier cooler for optimum moisture removal
- Large variety of vial sizes including septum-closed vials
- Allows a true system blank analysis
- Method according to EPA 415.1, Standard Methods 5310B, DIN 38409 H3, ASTM D-5173, USP <643>, EU 2.2.44, ISO 8245, EN 1484, USEPA 9060A
PrimacsMCS Features
- Automatic balance interfacing
- Sample weights up to 3 grams
- Range of 1 mg to 40 mg absolute carbon
- Unique vertical sample introduction system
- Reusable quartz sample crucibles
- Economical concept
- Requires minimal bench space
- Integrated TC and TIC reactors
- No sample pretreatment required
- Method according ISO 10649, ISO 13137, EN 13639 , EPA 415.1, ASTM D-2579 US, EPA 9060A
analyze TOC in:
- Drinking water
- Waste water
- Surface water
- Sea water
- High saline waters
- Process control
- Pharmaceutical industry
- Soil extracts
- Others
free for rental