Offers speed, accuracy and high performance for all your CD test needs in the CO and in the field. Combines with the FLS-5800A light source, which is designed for both PMD and chromatic dispersion (CD) testing.
Polarization Mode Dispersion Analyzer:
- Less than five-second testing time for any PMD range
- No auto-correlation peak, for enhanced accuracy
- NIST traceable
- Ideal for aerial fibers
- Patented design*: test through EDFAs
- 100 Gbit/s-ready
Chromatic Dispersion Analyzer:
- Complete CD characterization
- Highly accurate phase-shift method
- No communication between source and receiver
- Patented design*: test through EDFAs
- 100 Gbit/s-ready
PMD analyzer:
- Wavelength range (nm): 1260 to 1675 (O to U band)
- Measurement range (ps): 0 to 115
- Sensitivity a (dBm): –45
- Measuring time (s): 4.5 (for any PMD value)
- Absolute uncertainty (strong mode coupling): (ps) ± (0.020 + 2 % of PMD)
- Allows measurement through EDFA: Yes (above 120 EDFAs)
- Operating temperature: 0 °C to 40 °C (32 °F to 104 °F)
- Storage temperature: –40 °C to 70 °C (–40 °F to 158 °F)
- Relative humidity 0 % to 93 % non-condensing
CD analyzer:
- Wavelength range (nm): 1530 to 1625
- Wavelength step (nm): Minimum 0.1
- Measurement points: Maximum 950, user-definable
- Dynamic range c (dB): 42
- Wavelength uncertainty d (accuracy) (nm): 0.1
- Dispersion uncertainty d (accuracy) (ps/nm):
- 20 km of G.652 - 1.6
- 120 km of G.652 - 3.1
- 20 km of G.655 - 1.9 (guaranteed)
- Dispersion repeatability d (ps/nm):
- 0.04 (20km); 0.2 (80km); 1.1 (120km)
- Zero-dispersion wavelength λ0 repeatability d (nm):
- 0.1(20km); 0.14 (80km); 0.8 (120km)
- Dispersion slope repeatability λ0 (%):
- 0.03(20km); 0.05(80km); 0.25(120km)
- Minimum fiber length (km): < 1
- Maximum fiber length e (km): > 5400
- Measurement time per point e (s): Minimum < 1
measuring CD and calculating PMD
free for rental
National Research Centers (VNPC)
|
-
|