Contacts and Location
Enquire about this equipment | |
Organisational Unit |
Riga Technical University Faculty of Electrical and Environmental Engineering Institute of Energy Systems and Environment - Latvia, Rīga |
Building | Riga, Azenes,12 k-1 |
Room | 107 |
Description
This stand is developed for implementation of controlled combustion tests in accordance with EN 303-5 and EN 13240 standards. It is designed for solid fuel boilers and stoves with capacity up to 35 kW. Measurable parameters: efficiency, capacity, combustion power, heat losses, temperature on surfaces, flue gas parameters (CO, NOx, CO2, O2, PM, temperature), draught, fuel consumption, flow rate and temperatures of the internal fluid, combustible content in ashes.
Specification
Services
Manufacturer
---
Model
---
Availability
Available on request
Portability
Stationary
Access Level
Full Access